{"id":453,"date":"2026-05-01T12:06:40","date_gmt":"2026-05-01T04:06:40","guid":{"rendered":"http:\/\/223.254.131.93:10098\/?post_type=product&#038;p=453"},"modified":"2026-05-10T14:44:23","modified_gmt":"2026-05-10T06:44:23","slug":"yjv","status":"publish","type":"product","link":"https:\/\/www.xqcables.com\/index.php\/product\/yjv\/","title":{"rendered":"YJV Power Cable 0.6\/1kV Unarmouered Low Voltage Cable to IEC60502-1 Standard XLPE\/PVC Cable"},"content":{"rendered":"<table style=\"border-collapse: collapse; width: 884.52pt;\" border=\"0\" width=\"1769\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 14.00pt;\">\n<td class=\"et2\" style=\"height: 14.00pt; width: 147.85pt;\" colspan=\"2\" width=\"295\" height=\"28\"><strong>Description<\/strong><\/td>\n<td style=\"width: 89.40pt;\" width=\"178\"><\/td>\n<td style=\"width: 100.40pt;\" width=\"200\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 69.45pt;\" width=\"138\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td class=\"et4\" style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<\/tr>\n<tr style=\"height: 39.25pt;\">\n<td class=\"et3\" style=\"height: 39.25pt; width: 884.55pt; border-right: 1.0pt solid #000000;\" colspan=\"14\" width=\"1769\" height=\"78\">YJV is a XLPE (cross-linked polyethylene) insulated, PVC sheathed power cable designed for fixed installation in power distribution networks. Rated 0.6\/1kV. Ideal for industrial plants, commercial buildings, infrastructure projects, and underground power transmission.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table style=\"border-collapse: collapse; width: 884.52pt;\" border=\"0\" width=\"1769\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 14.00pt;\">\n<td class=\"et2\" style=\"height: 14.00pt; width: 67.40pt;\" width=\"134\" height=\"28\"><strong>Application<\/strong><\/td>\n<td style=\"width: 80.45pt;\" width=\"160\"><\/td>\n<td style=\"width: 89.40pt;\" width=\"178\"><\/td>\n<td style=\"width: 100.40pt;\" width=\"200\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 69.45pt;\" width=\"138\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<td class=\"et4\" style=\"width: 53.05pt;\" width=\"106\"><\/td>\n<\/tr>\n<tr style=\"height: 33.00pt;\">\n<td class=\"et3\" style=\"height: 33.00pt; width: 884.55pt; border-right: 1.0pt solid #000000;\" colspan=\"14\" width=\"1769\" height=\"66\">It is suitable for fixed installation in power transmission and distribution lines such as urban power grids, industrial power distribution, building electrical systems, tunnels, and cable trenches, particularly where high current carrying capacity and thermal performance are required.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table style=\"border-collapse: collapse; width: 237.03pt;\" border=\"0\" width=\"474\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 14.00pt;\">\n<td class=\"et2\" style=\"height: 14.00pt; width: 147.85pt;\" colspan=\"2\" width=\"295\" height=\"28\"><strong>Key Specifications:<\/strong><\/td>\n<td style=\"width: 89.40pt;\" width=\"178\"><\/td>\n<\/tr>\n<tr style=\"height: 14.00pt;\">\n<td class=\"et3\" style=\"height: 14.00pt;\" colspan=\"2\" height=\"28\">Parameter<\/td>\n<td class=\"et3\">Value<\/td>\n<\/tr>\n<tr style=\"height: 14.00pt;\">\n<td class=\"et3\" style=\"height: 14.00pt;\" colspan=\"2\" height=\"28\">Voltage rating<\/td>\n<td class=\"et4\" style=\"width: 89.40pt;\" width=\"178\">0.6\/1kV<\/td>\n<\/tr>\n<tr style=\"height: 56.00pt;\">\n<td class=\"et3\" style=\"height: 56.00pt;\" colspan=\"2\" height=\"112\">Insulation material<\/td>\n<td class=\"et4\" style=\"width: 89.40pt;\" width=\"178\">XLPE (cross-linked polyethylene) \u2013 thermoset<\/td>\n<\/tr>\n<tr style=\"height: 28.00pt;\">\n<td class=\"et5\" style=\"height: 28.00pt; border-right: .5pt solid #000000;\" colspan=\"2\" height=\"56\">Sheath (Jacket)<\/td>\n<td class=\"et4\" style=\"width: 89.40pt;\" width=\"178\">PVC (polyvinyl chloride)<\/td>\n<\/tr>\n<tr style=\"height: 84.00pt;\">\n<td class=\"et7\" style=\"height: 84.00pt; width: 147.85pt; border-right: .5pt solid #000000;\" colspan=\"2\" width=\"295\" height=\"168\">Conductor cross section range<\/td>\n<td class=\"et4\" style=\"width: 89.40pt;\" width=\"178\">1.5 \/ 2.5 \/ 4 \/ 6 \/ 10 \/ 16 \/ 25 \/ 35 \/ 50 \/ 70 \/ 95 \/ 120 \/ 150 \/ 185 \/ 240 mm\u00b2<\/td>\n<\/tr>\n<tr style=\"height: 70.00pt;\">\n<td class=\"et5\" style=\"height: 70.00pt; border-right: .5pt solid #000000;\" colspan=\"2\" height=\"140\">Number of cores<\/td>\n<td class=\"et4\" style=\"width: 89.40pt;\" width=\"178\">1, 2, 3, 4, 5 cores (3+1, 3+2, 4+1 core configurations available)<\/td>\n<\/tr>\n<tr style=\"height: 28.00pt;\">\n<td class=\"et3\" style=\"height: 28.00pt;\" colspan=\"2\" height=\"56\">Sheath color<\/td>\n<td class=\"et4\" style=\"width: 89.40pt;\" width=\"178\">Black (standard for outdoor\/UV)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"781\">\n<tbody>\n<tr>\n<td colspan=\"3\" width=\"474\"><strong>Model and Parameters<\/strong><\/td>\n<td width=\"200\"><\/td>\n<td width=\"106\"><\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>Name<\/td>\n<td>Rated Voltage<\/td>\n<td>Normal area(mm\u00b2)<\/td>\n<td width=\"106\">Max Resistance @20\u2103(\u03a9\/km)<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td rowspan=\"15\" width=\"160\">Copper Conductor,Unarmouered Low Voltage XLPE Insulated PVC Sheathed Power Cable<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>1.5<\/td>\n<td>12.1<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>2.5<\/td>\n<td>7.41<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>4.0<\/td>\n<td>4.61<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>6.0<\/td>\n<td>3.08<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>10.0<\/td>\n<td>1.83<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>16.0<\/td>\n<td>1.15<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>25.0<\/td>\n<td>0.727<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>35.0<\/td>\n<td>0.524<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>50.0<\/td>\n<td>0.387<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>70.0<\/td>\n<td>0.268<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>95.0<\/td>\n<td>0.193<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>120.0<\/td>\n<td>0.153<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>150.0<\/td>\n<td>0.124<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>185.0<\/td>\n<td>0.099<\/td>\n<\/tr>\n<tr>\n<td>YJV<\/td>\n<td width=\"178\">0.6\/1kV<\/td>\n<td>240.0<\/td>\n<td>0.075<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table width=\"563\">\n<tbody>\n<tr>\n<td colspan=\"4\" width=\"457\"><strong>Aluminum Conductor Version (YJLV):<\/strong><\/td>\n<td width=\"106\"><\/td>\n<\/tr>\n<tr>\n<td>Model<\/td>\n<td>Name<\/td>\n<td width=\"106\">Rated Voltage<\/td>\n<td width=\"106\">Normal area(mm\u00b2)<\/td>\n<td width=\"106\">Max Resistance @20\u2103(\u03a9\/km)<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td rowspan=\"10\" width=\"138\">Aluminum Conductor,Unarmouered Low Voltage XLPE Insulated PVC Sheathed Power Cable<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>16.0<\/td>\n<td>1.91<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>25.0<\/td>\n<td>1.200<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>35.0<\/td>\n<td>0.868<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>50.0<\/td>\n<td>0.641<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>70.0<\/td>\n<td>0.443<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>95.0<\/td>\n<td>0.320<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>120.0<\/td>\n<td>0.253<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>150.0<\/td>\n<td>0.206<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>185.0<\/td>\n<td>0.164<\/td>\n<\/tr>\n<tr>\n<td>YJLV<\/td>\n<td width=\"106\">0.6\/1kV<\/td>\n<td>240.0<\/td>\n<td>0.125<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<table style=\"border-collapse: collapse; width: 337.52pt;\" border=\"0\" width=\"675\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et2\" style=\"height: 18.00pt; width: 337.65pt;\" colspan=\"4\" width=\"675\" height=\"36\">YJV Series \u2013 Flame Retardant\/Fireproof Upgrade Model<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et2\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Flame Retardant Grades (ZR-YJV):<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Grade Code Test Standard Application<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Class C ZC-YJV IEC 60332-3-24 (C) General flame retardant<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Class B ZB-YJV IEC 60332-3-23 (B) Higher requirement<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Class A ZA-YJV IEC 60332-3-22 (A) Highest \u2013 critical facilities<\/td>\n<\/tr>\n<tr style=\"height: 7.00pt;\">\n<td class=\"et3\" style=\"height: 7.00pt;\" height=\"14\"><\/td>\n<td class=\"et3\"><\/td>\n<td class=\"et3\"><\/td>\n<td class=\"et3\"><\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et2\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Fire Resistant (NH-YJV):<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Feature Specification<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Construction XLPE insulation + mica glass tape over conductor<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Test standard IEC 60331 (950\u00b0C flame, 90 minutes)<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Circuit integrity Yes \u2013 continues to conduct during fire<\/td>\n<\/tr>\n<tr style=\"height: 18.00pt;\">\n<td class=\"et3\" style=\"height: 18.00pt;\" colspan=\"4\" height=\"36\">Best for Fire pumps, emergency lighting, fire alarms, evacuation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>Description YJV is a XLPE (cross-linked polyethylene) insulated, PVC sheathed power cable designed for fixed installation in power distribution networks. Rated 0.6\/1kV. Ideal for industrial plants, commercial buildings, infrastructure projects, and underground power transmission. &nbsp; Application It is suitable for fixed installation in power transmission and distribution lines such as urban power grids, industrial power [&hellip;]<\/p>\n","protected":false},"featured_media":455,"template":"","meta":[],"product_brand":[],"product_cat":[33,52],"product_tag":[],"class_list":{"0":"post-453","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-power-control-cables","7":"product_cat-yjv","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.xqcables.com\/index.php\/wp-json\/wp\/v2\/product\/453","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.xqcables.com\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.xqcables.com\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.xqcables.com\/index.php\/wp-json\/wp\/v2\/media\/455"}],"wp:attachment":[{"href":"https:\/\/www.xqcables.com\/index.php\/wp-json\/wp\/v2\/media?parent=453"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.xqcables.com\/index.php\/wp-json\/wp\/v2\/product_brand?post=453"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.xqcables.com\/index.php\/wp-json\/wp\/v2\/product_cat?post=453"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.xqcables.com\/index.php\/wp-json\/wp\/v2\/product_tag?post=453"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}